Urmston
New build apartment scheme featuring 31no apartments. Olympian were engaged by the main contractor to design, install, commission and handover
-Landlords area
-Fire detection system
-EVAC system
-Natural AOV smoke ventilation system comprising natural double sided smoke shaft over 3 levels with associated stairwell ventilation.
-Landlords area
-Fire detection system
-EVAC system
-Natural AOV smoke ventilation system comprising natural double sided smoke shaft over 3 levels with associated stairwell ventilation.
Altrincham
A new build scheme of luxury apartments on the banks of the Bridgewater canal. We worked on behalf of the M&E contractor and provided:-
Design, installation and commissioning covering
-Landlords Fire Alarm System
-Mechanical smoke ventilation system based on two four level smoke shafts with associated single stairwell ventilation
-Disabled Refuge Alarm
Design, installation and commissioning covering
-Landlords Fire Alarm System
-Mechanical smoke ventilation system based on two four level smoke shafts with associated single stairwell ventilation
-Disabled Refuge Alarm
High Wycombe
Refurbishment of existing commercial building converted to apartments and 3no new build apartment blocks on a podium with a large semi enclosed car park below.
Engaged by the M & E contractor Olympian provided design, installation, commission and handover of the following systems.
Landlords area fire alarm systems to common areas within 4no blocks and a below podium car park.
-Four panels on a fault tolerant network
A mix of natural and mechanical AOV systems to lobbies, corridors and stairwells and a mechanical system featuring 10no fans within the car park with Carbon Monoxide monitoring.
Positive Pressure Vents (PPV's) to stairwells from car park level.
Engaged by the M & E contractor Olympian provided design, installation, commission and handover of the following systems.
Landlords area fire alarm systems to common areas within 4no blocks and a below podium car park.
-Four panels on a fault tolerant network
A mix of natural and mechanical AOV systems to lobbies, corridors and stairwells and a mechanical system featuring 10no fans within the car park with Carbon Monoxide monitoring.
Positive Pressure Vents (PPV's) to stairwells from car park level.
Warrington
Olympian Fire have been the incumbent fire systems provider for our life sciences client for over 20 years.
We recently designed and installed Gas Suppression systems to 2no new clean room facilities.
Our works included full mechanical and electrical elements installation. We provided an IG55 system complete with double knock detection covering the clean room and change rooms and ceiling voids.
We recently designed and installed Gas Suppression systems to 2no new clean room facilities.
Our works included full mechanical and electrical elements installation. We provided an IG55 system complete with double knock detection covering the clean room and change rooms and ceiling voids.
Timperley
New build luxury apartment scheme in the heart of Timperly village. Olympian were engaged by the main contractor to complete the smoke ventilation system AOVs consisting two mechanical smoke shafts over four levels and the associated single staircase.
Saunderton
A stunning Art Deco former office building in the Buckinghamshire countryside converted to high end residential apartments. The apartments featured a simply beautiful courtyard landscaped communal garden.Olympian Fire worked alongside the M&E contractor and provided the inspiration and commission of 2no L5 fire detection systems to cover the common/landlords areas and natural smoke shaft systems, corridor windows to vent at 1.5m2 along with 4 no associated stairwells
Edinburgh
Edinburgh New build luxury student accommodation scheme where Olympian were awarded the smoke ventilation package by the M&E contractor.
We provided a mechanical smoke shaft covering 5 levels with temp stats for corridor over heating. In addition the top floor level featured 1.5m2 natural ventilation above corridor and the 2no associated stairwells were naturally vented with 1.0m2 polycarbonate roof mounted vents.
We provided a mechanical smoke shaft covering 5 levels with temp stats for corridor over heating. In addition the top floor level featured 1.5m2 natural ventilation above corridor and the 2no associated stairwells were naturally vented with 1.0m2 polycarbonate roof mounted vents.
Woolwich
Olympian provided the supply installation and commissioning of fire alarms and EVAC systems to 2no high rise luxury apartment schemes on the banks of the Thames.
We used Advanced MxPro5 panels in both 4 and 8 loop formats with Hochiki detection protocols. The EVAC systems we provided were CTec manufactured with controls in a GERDA box and featured single apartment interfaces and white self test sounders.
We used Advanced MxPro5 panels in both 4 and 8 loop formats with Hochiki detection protocols. The EVAC systems we provided were CTec manufactured with controls in a GERDA box and featured single apartment interfaces and white self test sounders.
University of Manchester
Olympian we're approached by the University Estates retained electrical contractors to undertake the upgrade of the fire alarm system within the stunning Whitworth Hall building. As an Eaton partner we supplied all the new Eaton equipment and commissioned the system.
Radisson Blu Hotel
A New 4 Star 154 Bedroom upmarket hotel with an ultra-cool rooftop bar situated as the name suggests in the heart of the city.
Engaged by the project M&E Contractors, Olympian Fire Protection Ltd Conducted the design, supply, installation testing and commissioning of the following life safety system.
Fire Detection Alarm System
A multi loop Cerberus pro Siemens analogue addressable fire detection and alarm system featuring full voice alarm notification and incorporating vibrating pillow discs for accessible bedrooms.
Mechanical Smoke Ventilation System
A Two shaft mechanical smoke ventilation system serving lobby area with damper and associated fire control switches. Standby with duty fans and controls at roof level with all associated ductwork. In addition, 4 stairwells were also vented with roof mounted ventilators with associated fire control switches. CFD Modelling was also carried out by Olympian Fire Protection Ltd.
Disabled Refuge & Assistance alarms
A combined refuge alarm communication system covering refuge area on escape staircase and providing two-way speech to control at the fire fighter’s entrance and reception area.
Disabled alarm kits connected to the refuge system featuring pull cord, reset buttons and overdoor indicator, lights and sounders have been provided in all accessible bedrooms and bathrooms.
Engaged by the project M&E Contractors, Olympian Fire Protection Ltd Conducted the design, supply, installation testing and commissioning of the following life safety system.
Fire Detection Alarm System
A multi loop Cerberus pro Siemens analogue addressable fire detection and alarm system featuring full voice alarm notification and incorporating vibrating pillow discs for accessible bedrooms.
Mechanical Smoke Ventilation System
A Two shaft mechanical smoke ventilation system serving lobby area with damper and associated fire control switches. Standby with duty fans and controls at roof level with all associated ductwork. In addition, 4 stairwells were also vented with roof mounted ventilators with associated fire control switches. CFD Modelling was also carried out by Olympian Fire Protection Ltd.
Disabled Refuge & Assistance alarms
A combined refuge alarm communication system covering refuge area on escape staircase and providing two-way speech to control at the fire fighter’s entrance and reception area.
Disabled alarm kits connected to the refuge system featuring pull cord, reset buttons and overdoor indicator, lights and sounders have been provided in all accessible bedrooms and bathrooms.